Altiplano Híbrido
Needs attentionMurcia · Wind + solar + storage · 74 MW installed · 8 technicians · manager Eleonore Hamill
11.2 MW
15 %
191 MWh
97.1 %
21 / 29
11
Wind
9.1 m/s W
Irradiance
0 W/m²
Temperature
16.2 °C
Cloud cover
28 %
Conditions
Sunny intervals
Substation
Yecla SE 220 kV
Voltage
220.3 kV
Frequency
49.987 Hz
Power factor
0.974
Curtailment
7 %
Day-ahead price
90.13 €/MWh
Assets
29 assets on site. Open one for its live 3D view.
Wind turbine
WTG-01
Siemens Gamesa SG 6.6-170 · 5.0 MW
Output
0.00 MW
Today
11.1 MWh
Wind
8.0 m/s
Wind turbine
WTG-03
Siemens Gamesa SG 6.6-170 · 4.2 MW
Output
0.00 MW
Today
16.3 MWh
Wind
3.3 m/s
Tracker block
PV-01
Nextracker NX Horizon · 2.4 MWp
Output
0.00 MW
Today
7.8 MWh
Availability
96.3 %
Tracker block
PV-03
Array Technologies DuraTrack HZ v3 · 2.4 MWp
Output
0.00 MW
Today
5.5 MWh
Availability
93.3 %
Tracker block
PV-04
Array Technologies DuraTrack HZ v3 · 4.0 MWp
Output
0.00 MW
Today
9.7 MWh
Availability
97.5 %
Tracker block
PV-08
Array Technologies DuraTrack HZ v3 · 2.4 MWp
Output
0.00 MW
Today
5.3 MWh
Availability
95.8 %
Tracker block
PV-09
Nextracker NX Horizon · 3.2 MWp
Output
0.00 MW
Today
9.0 MWh
Availability
99.7 %
Tracker block
PV-11
Array Technologies DuraTrack HZ v3 · 4.0 MWp
Output
0.00 MW
Today
9.1 MWh
Availability
98.7 %
Tracker block
PV-14
Array Technologies DuraTrack HZ v3 · 4.0 MWp
Output
0.00 MW
Today
11.0 MWh
Availability
97.3 %
Inverter skid
INV-01
Sungrow SG3125HV-MV · 4.6 MVA
Output
0.00 MW
Today
10.2 MWh
Availability
96.9 %
Inverter skid
INV-02
Sungrow SG3125HV-MV · 3.1 MVA
Output
0.97 MW
Today
9.9 MWh
Availability
96.6 %
Inverter skid
INV-03
Huawei SUN2000-215KTL · 5.0 MVA
Output
0.00 MW
Today
15.1 MWh
Availability
99.4 %
Inverter skid
INV-04
Huawei SUN2000-215KTL · 3.1 MVA
Output
0.00 MW
Today
4.3 MWh
Availability
95.4 %
Inverter skid
INV-05
SMA Sunny Central 4600 UP · 4.6 MVA
Output
0.70 MW
Today
11.7 MWh
Availability
98.5 %
Inverter skid
INV-06
Huawei SUN2000-215KTL · 4.6 MVA
Output
0.33 MW
Today
13.5 MWh
Availability
99.5 %
Inverter skid
INV-07
SMA Sunny Central 4600 UP · 4.6 MVA
Output
0.01 MW
Today
15.1 MWh
Availability
98.7 %
Battery container
BESS-01
CATL EnerOne+ · 5.0 MW
Output
-3.65 MW
Today
1.4 MWh
State of charge
87 %
Battery container
BESS-02
CATL EnerOne+ · 3.9 MW
Output
-2.89 MW
Today
1.1 MWh
State of charge
87 %
Blade ice detected
Row stowed – high wind
IGBT temperature high
Blade ice detected
Module temperature above limit
Soiling loss above threshold
Communication lost to controller
Power limited by temperature